Does Your Inner West Solar Inverter's DC Isolator Switch Both Wires at Once?
Does your Inner West solar inverter's DC isolator switch both wires at once? It needs to. The Service and Installation Rules of NSW require a double pole DC isolation device fitted at or inside the inverter, switching the positive and negative legs of the solar array together in a single action, not one after the other. A DC isolator that only breaks one leg, or that can leave one conductor live while the other is open, does not meet the rule and is a genuine safety gap on a rooftop system.
⚡ Quick Answers: Double Pole DC Isolation for Inner West Solar
- What does double pole actually mean here? Both the positive and negative DC conductors coming from the solar array switch off together, in the same action, rather than one switching and the other staying connected.
- Where does this isolator have to be fitted? At the inverter itself, or built into it, under SIRNSW Clause 8.6.10.
- Why does a single pole isolator fail this rule? Because it can leave one DC conductor still carrying voltage from the panels even after the isolator is switched off, which defeats the point of isolating the array at all.
- Does this replace the isolator at the panels themselves? No, a rooftop array isolator at the panels is a separate requirement again, and both isolators work together, not instead of each other.
- Is this the same rule as the inverter's automatic disconnection device? No, the automatic disconnection device covers the alternating current side and reacts to grid conditions, while this rule covers the direct current side and is a manual isolation point.
- Who checks this on an existing system? Your Level 2 electrician or solar installer, usually during a safety inspection, a battery addition or any switchboard work that touches the existing solar connection.
1. What a DC Isolator Is Actually For
Unlike a normal household circuit, a solar array cannot simply be switched off at a breaker the way the rest of your home can. Sunlight keeps generating a direct current voltage across the panels for as long as light is hitting them, breaker or no breaker. A DC isolator exists specifically to give a technician, or an emergency responder, a defined point to physically disconnect that array from the rest of the system.
Because that disconnection point has to actually work under fault conditions, not just in ordinary daily use, the rules around how it switches are more specific than most people expect.
2. The Double Pole Rule Under SIRNSW Clause 8.6.10
SIRNSW Clause 8.6.10 requires a double pole DC isolation device, fitted at or in the inverter, that switches both the positive and the negative DC legs at the same time. A single pole device, one that only interrupts one of the two conductors, does not satisfy this rule even if it happens to be rated for the right voltage and current.
The reasoning is straightforward once you think about what a single pole isolator actually leaves behind. If only the positive leg switches off, the negative conductor can still be carrying a voltage relative to earth, depending on how the array is configured and whether an earth fault exists elsewhere in the string. A technician who assumes the array is fully isolated because the switch has been operated is working on a system that is not actually dead.
3. Why Both Legs Have to Open Together
A solar array is a direct current source for as long as light reaches the panels, and that current does not behave the same way a mains supply does when a single pole is interrupted. Opening only one leg of a two wire DC circuit does not guarantee the other leg is safe to touch, because the DC source keeps pushing current through whatever path remains, including through a person who contacts the still connected conductor and an earthed surface.
A double pole isolator removes that ambiguity entirely. Both conductors break in the same mechanical action, so there is no scenario where one leg is open and the other is still live. This is the same logic that sits behind proper solar panel earthing and bonding on a terrace roof, where getting every part of the isolation and earthing chain right matters more than any single component in isolation.
4. At or In the Inverter, Not Somewhere Else
The rule is also specific about location. The double pole DC isolator has to be fitted at the inverter or built into it, not somewhere else along the DC cable run back from the panels. This is a separate requirement to the isolator fitted up at the array itself, which most rooftop systems also carry so a technician working on the roof has a disconnection point without walking back down to the inverter.
Both isolators exist for different reasons and neither one replaces the other. The array isolator lets someone isolate the panels before working on the roof. The inverter side double pole isolator lets someone isolate the DC input before working on or near the inverter itself, which is usually mounted inside a garage, a hallway or a switchboard area rather than on the roof.
5. How This Differs From the Automatic Disconnection Device
It is easy to confuse this rule with the inverter's automatic disconnection device, which we cover in full in our guide to what your solar inverter's automatic disconnection device actually has to do, but the two cover entirely different sides of the system. The automatic disconnection device isolates the alternating current output to the grid, and it reacts automatically to voltage and frequency conditions without anyone touching a switch.
The double pole DC isolator covered here is the opposite in almost every respect. It sits on the direct current side, between the panels and the inverter's internal circuitry, and it is a manual device a person operates on purpose, not an automatic protection response. A compliant system needs both, doing two different jobs, and neither one is a substitute for the other.
6. What This Looks Like on an Inner West Terrace or Semi
On a typical Inner West terrace or semi, the inverter is often mounted in a tight hallway, a garage wall or close to the main switchboard, with limited space around it. That makes a compliant, clearly accessible double pole isolator even more important, since there is rarely room for a technician to improvise an alternative isolation point if the proper one is missing or hard to reach.
It also matters when a battery system is added to an existing solar installation, since any switchboard work that touches the original solar connection is a natural point to check that the existing inverter isolation still meets the rule, particularly on an older system installed before this requirement was commonly enforced.
7. What to Check if Your System Predates This Rule
Older solar installations, particularly ones put in before the rule was consistently applied, sometimes have a single pole isolator at the inverter rather than a proper double pole device. This is not something most homeowners would ever notice on their own, since the system keeps generating and exporting power exactly as expected whether the isolator is compliant or not.
It tends to surface at a safety inspection, when a battery is added, or when an inverter itself is replaced and the installer actually inspects the existing isolation arrangement rather than just swapping the unit. If your system is more than a few years old and you have never had the DC isolation specifically checked, it is a reasonable thing to ask about at your next service.
How High Demand Electrical Inner West Helps
High Demand Electrical Inner West is a licensed local team, not a call centre, servicing homes and businesses across Sydney's inner west. Whether you are adding a battery to an existing solar system, upgrading your switchboard, or simply want an older solar installation properly checked, we confirm the inverter's DC isolation actually meets the double pole requirement rather than assuming an older system is fine because it still produces power.
Solar DC Isolator FAQs (Sydney)
Does every solar inverter need a double pole DC isolator?
Yes, under SIRNSW Clause 8.6.10 every grid connected solar inverter needs a double pole DC isolation device fitted at or in the inverter, regardless of system size.
Is a single pole isolator ever acceptable?
No. A single pole device can leave one DC conductor still carrying voltage even after it is switched, which does not satisfy the rule or provide genuine isolation.
Does the panel level isolator on the roof replace this requirement?
No. The rooftop array isolator and the inverter's double pole DC isolator are separate requirements that work together, not as substitutes for one another. See our guide to solar panel earthing and bonding on a terrace roof for how the full isolation and earthing chain fits together.
How would I know if my existing system is compliant?
Ask your electrician to check it specifically at your next electrical safety inspection or whenever switchboard work is being carried out nearby, since it is not something that shows up as a fault in day to day use.
Does adding a battery affect this requirement?
Adding a battery does not change the DC isolation rule itself, but the work involved is a natural opportunity to check the existing inverter isolation while the switchboard is already open. See our guide to solar battery switchboard labelling for the related labelling requirements that often come up at the same time.
Adding a battery, upgrading your switchboard, or want your existing solar system properly checked? Get a Switchboard Upgrade Quote or call 0402 559 777. Every job needs a proper site assessment before scope or pricing can be confirmed, since the right isolation check depends on your actual inverter and installation.
Related reading: what your solar inverter's automatic disconnection device actually has to do and solar and battery systems on Inner West terrace roofs. On the Power Pole site: does a CT metered private power pole need its own 240 volt contactor. On the main site: Level 2 electrician Sydney.
Powering Your Needs with Expertise
If you want a reliable, experienced, and prompt electrician, High Demand Electrical Inner West is the one to call. We cover every electrical need — routine maintenance, emergency repairs, full system installs — and our team is focused on keeping your setup running smoothly. Small task or big project, give us a ring today.